38 Reference & Installation Manual
16 WinLoad Software
16.1 Panel Identifier
SECTION [3011]
(default = 0000) Program the same Panel Identifier in the control panel and
WinLoad. WinLoad will establish communication on matching identifier.
Enter the desired 4-digit hexadecimal number into section [3011].
16.2 PC Password
SECTION [3012]
(default = 0000) Program the same Password in the control panel and
WinLoad. WinLoad will establish communication on matching passwords.
Enter the desired four-digit hexadecimal number into section [3012].
16.3 PC Telephone Number
SECTION [3010]
The control panel dials this number to communicate with a computer using
WinLoad. Enter any digit from 0 to 9 and any special keys or functions (see
Table 4: Special Telephone Number Keys on page 24) up to a maximum of
32 digits into section [3010].
16.4 Call Back Feature
SECTION [3037]: OPTION [1]
(default = disabled) If enabled and a computer using WinLoad attempts to
communicate with the control panel, the control panel hangs up and calls
the computer back to verify identification codes and establish
communication. When the control panel hangs up, WinLoad automatically
goes into Wait For Call Mode (see “WinLoad’s Online Help”), ready to
answer when the control panel calls back. The PC Telephone Number must
be programmed.
16.5 Call WinLoad
Dial the PC Telephone Number programmed in section [3010] to
communicate with WinLoad. The control panel and WinLoad verify that the
Panel Identifier and the PC Password match before establishing
communication.
WinLoad must be in Wait For Call Mode (see WinLoad’s Online
Help).
For LCD Keypads: Press and hold the [0] key, enter your [
INSTALLER
CODE] and then press [FORCE].
For Grafica Keypads: Press and hold the [0] key, enter your [INSTALLER
CODE], press the center action key (Options), highlight Call WinLoad and
then press the left action key (Select).
16.6 Answer WinLoad
To upload/download on-site, connect the computer to the control panel
using an ADP-1 line adapter. In WinLoad set Dialing Condition to Blind Dial,
program the PC telephone number and follow the ADP-1 Adapter‘s
instructions. When the computer has dialed:
For LCD Keypads: Press and hold the [0] key, enter the [
INSTALLER CODE]
and press [
ARM] to answer WinLoad. Press [DISARM] to hang up.
For Grafica Keypads: Press and hold the [0] key, enter the [INSTALLER
CODE], press the center action key (Options), highlight Answer WinLoad
and then press the left action key (Select). To hang up, highlight Cancel
Communication and then press the left action key (Select).
16.7 Answering Machine Override Delay
SECTION [3052]
(default = 008) Program the Answering Machine Override if WinLoad is
used to communicate with an installation that uses an answering machine
or service.
Program a value (00 to 15 X 4 seconds, 00 = disabled) representing the
delay period the control panel will wait between the first and second call.
To use:
1. Call the installation and, with Winload, press [
ENTER] on the keyboard
or hang up manually on the second ring.
2. After hanging up, WinLoad immediately calls the installation back or
call back manually.
16.8 Ring Counter
SECTION [3051]
(default = 008) The Ring Counter represents the number of rings the control
panel will wait before picking up the line. If more than 10 seconds pass
between each ring, the Ring Counter resets. Enter any value between 01 to
15 (00 = disabled).
16.9 Event Buffer Transmission
SECTION [3037]: OPTION [2]
(default = disabled) Once the Event Buffer contains 1998 events, the
control panel makes two attempts to establish communication through
WinLoad by calling the PC Telephone Number programmed in section
[3010]. WinLoad must be in Wait To Dial mode.The control panel uploads
the contents of the Event Buffer to WinLoad. If communication is interrupted
before completing transmission or communication is not established after
two attempts, the control panel wait until the Event Buffer receives another
1998 events before attempting Event Buffer Transmission.The Event Buffer
can hold 2048 Events.If it is full, new event will erase old ones.
16.10 In-Field Firmware Upgrade
1. Connect the CONV4USB or the 307USB to the “Serial” or “Upgrade”
port of the module or panel as shown in Figure 21 and Figure 22 on
page 39.
2. Start WinLoad and click on the In-Field Firmware Programmer button.
If your control panel is not automatically detected, click the Com
port settings button and select the correct Com port. Then, click
the Refresh Product Info button to connect with the panel.
3. Verify the product information located in the window.
4. In the drop down menu, select the most recent version of the firmware.
5. Use this button to load additional firmware files from another location
or click Download firmware from the web to get the latest firmware
online.
6. Click on Update product firmware.
If the upgrade process is not completed properly, either because Cancel was
pressed or because of technical problems, the panel or module will not function
until a firmware is properly transferred.