10 Dialer Options
10.1 Telephone Line Monitoring
SECTION [3036]: OPTIONS [1] AND [2]
When enabled, the system verifies the existence of the main telephone line
once every second. After each successful test, the Status LED on the
control panel flashes briefly. A line test failure occurs when the TLM detects
less than 3 volts for the period defined by the TLM Fail Timer (see section
10.1.1). If the line test fails, the control panel will generate one or more
conditions as defined by the TLM settings below, until it detects the
telephone line again. When the dialer detects a telephone ring, the TLM
test stops for 1 minute.
10.1.1 TLM Fail Timer
SECTION [3053]
(default = 016) If the TLM does not detect the existence of the main
telephone line for the time programmed in this section, the control panel will
generate the condition(s) defined by the TLM options (see section 10.1).
Enter any value between 016 and 255 (value is X2 seconds) into section
[3053]. Entering a value between 000 and 016 will set the TLM Fail Timer
to 32 seconds.
10.2 Tone/Pulse Dialing
SECTION [3036]: OPTION [4]
(default = enabled)
10.3 Pulse Ratio
SECTION [3036]: OPTION [5]
(default = enabled) When using Pulse dialing (see section 10.2), select one
of two Pulse Ratios. If the selected pulse ratio does not provide adequate
results, try the other one.
10.4 Busy Tone Detection
SECTION [3036]: OPTION [6]
(default = enabled) When enabled, the control panel immediately hangs up
if it receives a busy signal when it dials an outside number.
10.5 Switch To Pulse
SECTION [3036]: OPTION [7]
(default = disabled) When is enabled, the control panel switches from tone
dialing to pulse dialing on the fifth attempt to report events to the monitoring
station. The control panel continues to use pulse dialing until it establishes
communication. When the control panel switches to another monitoring
station telephone number, it returns to tone dialing and switches back to
pulse dialing on the fifth attempt.
10.6 Bell On Communication Fail
SECTION [3036]: OPTION [8]
(default = disabled) When enabled and the control panel fails to
communicate with the monitoring station when the partition is armed, the
control panel can enable the BELL output.
10.7 Keypad Beep on Successful Arm or Disarm Report
SECTION [3037]: OPTION [5]
(default = disabled) When enabled and a user arms or disarms a partition,
the keypad emits a beep tone to confirm that the monitoring station
received the arming or disarming report code.
10.8 Dial Tone Delay
SECTION [3037]: OPTION [7]
(default = disabled)
If more time is required, insert a 4-second pause into the desired telephone
number sequence (see section 9.4).
[1] [2] Feature When the line test fails
OFF OFF Disabled TLM disabled (default) .
ON OFF Trouble Only
The Communicator trouble appears in the
Trouble Display.
OFF ON
Alarm when
Armed
The Communicator trouble appears in the
Trouble Display. If the partition is armed, the
control panel generates an alarm.
ON ON
Silent Alarms
become Audible
The Communicator trouble appears in the
Trouble Display. The control panel switches
any triggered Silent Alarm zones or Silent
panic alarms to an audible alarm.
[4] ON Tone/DTMF format
[4] OFF Pulse dialing format
[5] ON North American pulse ratio of 1:1.5
[5] OFF European pulse ratio of 1:2
[7] ON If no dial tone is present, dialer hangs up after 32 secs.
[7] OFF If no dial tone is present, force dials after 3 secs.