EVO Control Panel 23
9.2.10 Special Alarm Report Codes
9.2.11 System Trouble Codes
9.2.12 System Trouble Restore Codes
If the Telephone Line Monitoring (see section 10.1) is disabled, the control panel will
not transmit the TLM report code.
9.3 Report Arming and Disarming
These features identify when partitions should be armed or disarmed. It
allow the control panel to report changes from the schedule.
9.3.1 Arming and Disarming Report Schedules
Arming and Disarming Report Schedules identify the days and times that a
partition should be armed and disarmed. Each schedule consists of 2
programmable time periods called Intervals that determine the time span
and days when the partition should be armed or disarmed (see Figure 17).
Schedules are enabled when they are programmed.
Figure 17: Example of an Arming and a Disarming Report Schedule
Program the Start Time and End Time according to the 24-hour clock and
enable the options representing the desired Days for the desired partition.
When option [8] is enabled, access is permitted during the programmed
holidays (see section 15.8 on page 36).
[3928] Remote Disarm
partition disarmed with InTouch Voice-
Assisted Arm/Disarm Module (APR3-ADM2)
[3930]
Emergency Panic
(non-medical)
the panic keys [1] and [3] were pressed
(see section 8.6 on page 20)
[3931] Auxiliary Panic
the panic keys [4] and [6] were pressed
(see section 8.6 on page 20)
[3932] Fire Panic
the panic keys [7] and [9] were pressed
(see section 8.6 on page 20)
[3933] Recent Closing
an alarm is generated within the Recent
Close Delay (see section 9.10 on page 25)
[3934] Police Code
Confirmation of an alarm condition occurred
during the Police Code Timer’s delay (see
section 8.4 on page 19).
[3935]
Auto Zone
Shutdown
the control panel stops regenerating alarms
on a zone during the same armed period
(see section 4.6.1 on page 11)
[3936] Duress
a Duress enabled access code is keyed in
(see Appendix 3: Keypad Installation
Instructions on page 44)
[3937] Keypad Lockout
too many invalid codes entered
(see section 7.19 on page 17)
[3941] AC Failure
AC power not detected. Also, see Power
Fail Report Delay in section 9.11
[3942] Battery Failure
battery is disconnected or the battery
voltage is less than or equal to 10.5V
[3943] Auxiliary Supply
the aux power supply’s current is greater
than or equal to 1.1A
[3944]
Bell Output
bell output is disconnected or the current
is greater than or equal to 3A
[3945] Clock Loss panel time lost (see section 13.17)
[3946] Fire Loop Trouble tamper on a Fire Zone (see section 4.4)
[3947] TO [3949] Future Use
[3950] Bus Fault a module was removed from the combus
[3951] Module Tamper
tamper/wire fault on module (not a motion
detector) on the combus
[3952] ROM Check Error on-board Read-Only Memory trouble
[3953] Module TLM
TLM failure detected on Listen-In Module
(DGP-LSN4)
[3954]
Module Fail to
Communicate
DGP2-DVAC failed to communicate with
the monitoring station
[3955] Printer Fault Printer Module detected an error
[3956] Module AC Failure no AC power detected on a module
[3957]
Module Battery
Failure
battery on a module is disconnected or the
battery voltage is low
[3958]
Module Auxiliary
Failure
the AUX output on a module has
exceeded current limits
[3959] Future Use
[3960]
Wireless Trans-
mitter Low Battery
the battery voltage is low on a wireless
transmitter
[3961]
Wireless Module
Supervision Failure
this report code is global unless using the
Contact ID or SIA reporting formats
[3962] to [3964] Future Use
[3965] Fail to Com 1 Phone Number 1 failed to communicate*
[3966] Fail to Com 2 Phone Number 2 failed to communicate*
[3967] Fail to Com 3 Phone Number 3 failed to communicate*
[3968] Fail to Com 4 Phone Number 4 failed to communicate*
* No “Fail to Communicate” for Pager telephone numbers
[3970] TLM1 Restored [3981] Module Tamper Restored
[3971] AC Restored [3982] ROM Check Error Restored
[3972] Battery Restored [3983] Module TLM Restored
[3973]
Auxiliary Supply
Restored
[3984]
Module Fail to Communicate
Restored
[3974] Bell Output Restored [3985] Printer Fault Restored
[3975] Clock Loss Restored [3986] Module AC Failure Restored
[3976] Fire Loop Restored [3987] Module Battery Restored
[3977] Future Use [3988] Module Auxiliary Restored
[3978] Future Use [3989] Future Use
[3979] Future Use [3990]
Wireless Transmitter Battery
Restored
[3980] Bus Fault Restored [3991]
Wireless Module Supervision
Restored
Arming Report Schedule
Partition 1: [3102] Partition 3: [3302] Partition 5: [3502] Partition 7: [3702]
Partition 2: [3202] Partition 4: [3402] Partition 6: [3602] Partition 8: [3802]
Disarming Report Schedule
Partition 1: [3103] Partition 3: [3303] Partition 5: [3503] Partition 7: [3703]
Partition 2: [3203] Partition 4: [3403] Partition 6: [3603] Partition 8: [3803]
Komentarze do niniejszej Instrukcji