SEKURE Paradox Digiplex DGP-610 Przewodnik Instalacji Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 64
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
EVO Control Panel 13
4.8 EOL on Hardwire Zones
SECTION [3033]: OPTION [7]
(default = disabled) If detection devices connected to hardwired input
terminals use 1k
Ω end of line resistors, enable option [7] in section [3033].
For details on using EOL resistors, refer to Addressable Zone Connections
on page 5 and Double Zone Connections on page 6.
4.9 Keypad Numbering
SECTIONS [2801] TO [2832]
Keypad Numbering identifies the keypad in the event buffer. The keypad is
assigned to a Keypad Number from 1 to 32 through the keypad's serial
number in sections [2801] to [2832].