Strona 1 - User Guide

Icon LCD Keypad(1640)User Guide1640-EU03.fm Page -3 Thursday, October 5, 2006 3:50 PM

Strona 2

6 User Guide2.4 Auditory FeedbackWhen you enter information on the keypad, it will guide you with beep tones. You should be familiar with these:Confir

Strona 3 - Table of Contents

1640 Icon LCD Keypad 73.0 Arming & DisarmingTake full advantage of your Spectra system by familiarizing yourself with all of the arming methods. I

Strona 4

8 User Guide3.3 Alarm Memory DisplayAll zones where alarms have occurred will be stored in memory. The system will erase the contents of the Alarm Mem

Strona 5 - 1.0 Introduction

1640 Icon LCD Keypad 93.5 Stay ArmingThis method allows you to remain in the protected area while partially arming the system. Stay Zones are zones th

Strona 6 - 2.0 Basic Operation

10 User Guide3.7 Force ArmingDuring Force Arming, any open zones are temporarily “deactivated” so you can rapidly arm the system without waiting for a

Strona 7 - 2.2 Keypad Indicator Lights

1640 Icon LCD Keypad 113.8 Manual Bypass ProgrammingManual Bypass Programming allows you to program the alarm system to ignore (deactivate) specified

Strona 8 - 2.3 On-screen Icons

12 User Guideentries saved in memory. This eliminates the need to manually reprogram the bypass entries every time you arm the system.3.9 One-Touch Ar

Strona 9 - Icon(s) Description

1640 Icon LCD Keypad 133.9.3 Exit and Stay ArmWith the system already Stay armed, press and hold the key for 3 seconds to start the Exit Delay (see

Strona 10 - 2.4 Auditory Feedback

14 User Guide3.10 Keyswitch ArmingA keyswitch can be used to arm and disarm the system. A keyswitch is programmed to Stay Arm (see page 9) or Regular

Strona 11 - 3.0 Arming & Disarming

1640 Icon LCD Keypad 15A 60-second Exit Delay (see page 7) will start before the system arms. Auto-Arming can be cancelled by entering your access cod

Strona 12 - 3.4 Regular Arming

1640-EU03.fm Page -2 Thursday, October 5, 2006 3:50 PM

Strona 13 - 3.6 Instant Arming

16 User GuideFigure 3.1: Delayed Fire Zone Event Sequence1640-EU03.fm Page 16 Thursday, October 5, 2006 3:50 PM

Strona 14 - 3.7 Force Arming

1640 Icon LCD Keypad 17Minimizing Fire HazardsThe three most common causes of fires:• Cooking is the leading cause of home fires in the U.S. It's

Strona 15 - 3.8 Manual Bypass Programming

18 User GuideProviding a Fire Warning SystemHousehold fires are especially dangerous at night. Fires produce smoke and deadly gases that can overcome

Strona 16 - 3.9 One-Touch Arming

1640 Icon LCD Keypad 194.0 Additional Features4.1 Programming Chime ZonesA Chime Enabled zone will advise you every time it is opened by causing your

Strona 17 - 1640 Icon LCD Keypad 13

20 User GuideEach keypad must be Muted separately. Keypad Muting must be reprogrammed if your system suffers a total power loss.4.3 Panic AlarmsIn cas

Strona 18 - 3.11 Timed Auto-Arming

1640 Icon LCD Keypad 214.4 Program Time 4.5 Quick Function Keys Upon request of your installer or monitoring station you may have to perform one of th

Strona 19 - 3.13 Fire Alarms

22 User Guide4.5.3 Answer PCPress the key, enter your [MASTER CODE] and press the key. This will force your security system to answer a call made b

Strona 20 - 16 User Guide

1640 Icon LCD Keypad 23installations where shared security systems are more practical, such as a home office or warehouse building. When partitioned,

Strona 21 - 1640 Icon LCD Keypad 17

24 User Guide5.0 Programming Access CodesAccess codes are personal identification numbers that allow you to enter certain programming modes, arm or di

Strona 22 - 18 User Guide

1640 Icon LCD Keypad 25used to create, modify or delete user access codes (see page 25) that are assigned to Area 1. Master Code 2 is permanently assi

Strona 23 - 4.0 Additional Features

Table of ContentsIntroduction...1Legend...

Strona 24 - 4.3 Panic Alarms

26 User GuideAfter entering the section number from Table 4, the 1640 will only display the first two digits of your code. Once you have entered the s

Strona 25 - 4.5 Quick Function Keys

1640 Icon LCD Keypad 276.0 Trouble ListYour alarm system continuously monitors fourteen possible trouble conditions. Most of these trouble conditions

Strona 26 - 4.7 Partitioning

28 User Guide[3] Power Failure The system has detected a loss of AC power. This trouble usually occurs during a power failure. If a power failure is n

Strona 27 - 4.8 Testing & Maintenance

1640 Icon LCD Keypad 29[8] Timer Loss Your alarm system’s clock must be reprogrammed. This is the only trouble that we recommend that you correct. Pre

Strona 28 - 5.0 Programming Access Codes

30 User Guide[13] Wireless Transmitter Supervision Loss A wireless transmitter is no longer communicating with its receiver or its batteries are disco

Strona 29 - 5.4 Programming Access Codes

1640 Icon LCD Keypad 317.0 System ChecklistIs this system partitioned? Yes N No NArea 1 = _________________________________________Area 2 = __

Strona 30 - ACCESS CODE]

32 User GuideAccess CodesFor security reasons, write only the user’s name and not his or her access code. 4-Digit Codes N 6-Digit Codes N13:____

Strona 31 - 6.0 Trouble List

1640 Icon LCD Keypad 33010:___________________ ____ NN N N011:___________________ ____ NN N N012:___________________ ____ NN N N013:__________________

Strona 32 - 28 User Guide

34 User Guide030:___________________ ____ NN N N031:___________________ ____ NN N N032:___________________ ____ NN N N033:___________________ ____ NN

Strona 33 - 1640 Icon LCD Keypad 29

1640 Icon LCD Keypad 35Special Buttons and FeaturesN One-touch Regular Arming is activatedN One-touch Stay Arming is activatedN One-touch Force

Strona 34 - 30 User Guide

Keypad Muting ...19Panic Alarms ...20Program Ti

Strona 35 - 7.0 System Checklist

36 User GuideWarrantyParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal

Strona 36 - Description

Notes1640-EU03.fm Page 37 Thursday, October 5, 2006 3:50 PM

Strona 37 - 1640 Icon LCD Keypad 33

1640-EU03.fm Page 38 Thursday, October 5, 2006 3:50 PM

Strona 38 - 34 User Guide

1640-EU03.fm Page 39 Thursday, October 5, 2006 3:50 PM

Strona 39 - 1640 Icon LCD Keypad 35

Printed in Canada - 05/2005 www.paradox.com 1640-EU031640-EU03.fm Page 40 Thursday, October 5, 2006 3:50 PM

Strona 40

1640 Icon LCD Keypad 11.0 IntroductionThe 1640 Icon LCD Keypad allows you to easily access your security system's functions and provide you with

Strona 41

2 User Guide2.0 Basic OperationThis section will provide an overview of the 1640’s functionality. This includes the use of action keys, indicator ligh

Strona 42

1640 Icon LCD Keypad 32.2 Keypad Indicator LightsThe state of each light on the 1640 keypad represents a specific condition in your system as shown in

Strona 43

4 User Guide2.3 On-screen IconsThe icons on the keypad’s screen communicate your system’s status as outlined in Table 3.Table 3: Icon Display Stat

Strona 44

1640 Icon LCD Keypad 5Indicates which areas are Instant Armed. Refer to Instant Arming on page 9.Indicates which areas are Stay Armed. Refer to Stay A