SEKURE Paradox Spectra 1686H Instrukcja Instalacji Strona 9

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 8
SPECT RA SERIES 7
2.7 BELL OUTPUT CONNECTION
The BELL+ and BELL- terminals power bells, sirens and other warning devices requiring a steady voltage output
during an alarm. The bell output supplies 12VDC upon alarm and can support one 30-watt or two 20-watt sirens.
The bell output uses a fuseless circuit and will automatically shut down if the current exceeds 3A. When this occurs
the Maximum Bell Current failure will only appear in the keypadsTr oubl e Di splay (see page 46) during an alarm. If
the load on the BELL terminals returns to normal, the control panel will re-instate power to the BELL terminals during
the next al arm. When connecting sirens, please verify correct pol ari ty. Connect the positive lead to the BELL+
terminal and the negative lead to the BELL- terminal of the control panel as shown in Figure 2.1 on page 4.
If the BELL output is not being used, the Bell Disconnected failure will remain in the keypads Trouble
Display (see pag e 46). To avoid this connect a 1K resistor across the BELL terminals.
2.8 PROGRAMMABLE OUTPUT CONNECTIONS
When a specific event occurs in the system, a PGM can reset smoke detectors, activate strobe lights, open/close
garage doors and much more.
2.8.1 PGM FOR 1728EX AN D 1728
The Spectra 1728/EX control panels include one on-board programmable output (PGM).
PGM1 provides a maximum 150mA output. If the current draw on the PGM is to exceed
the current output, we r ecommend the use of a relay as shown in Figure 2- 2. For details
on how to program the PGM, refer to PGM Programming on page 37.
2.8.2 ALA RM RELAY AND PGMS FOR 1738EX AND 1738
The Spectra 1738/EX control panel includes two on-board programmable outputs
(PGMs). For details on how to program the PGM, refer to PGM Programmi ng on
page 37. PGM1 can support up to 150mA while PGM2 supports up to 2.5A (see Figure
2.4 on page 7) and can be used as a strobe output (see page 38). The PGMs are limited
by the power source being used. If powered by:
The
AUX
terminals.
The current consumption of the
AUX
terminals cannot exceed 700mA. Therefore, whatever devices
are connected to the
AUX
terminals (i.e. modules and PGMs) cannot exceed 700mA combined. For example, if there are
six modules connected to the
AUX
terminals that are using 600mA and you wish to power the PGM using the
AUX
ter mi-
nals, the PGMs current consumption will not 100mA.
An ex te rna l p ow er su ppl y.
If using an external power supply, the current consumption cannot exceed 150mA for PGM1 and 2.5A for
PGM2. If the external power supply’s current consumption limit is less than that of the PGM it is connected to, than the current con-
sumption will not exceed the power supply’s current limit.
The Spectra 1738/EX control panels also have an optional 5A relay. This relay can be connected as shown in Figure
2.4. The Alarm Relay can be programmed to follow the bell output or the activation and deactivation of the Global
PGM (see Alarm Relay Opti ons on page 38).
Figure 2.4: Relay and PGM Connections
Figure 2.3: PGM
AU X + or External Power Supply. See
Programmable O utput Conn ectio ns on
page 7
Przeglądanie stron 8