12 REFERENCE & INSTALLATION MANUAL
3.3 CONFIGURING THE LED KEYPADS
Depending on the version of the keypad, two methods can be used to configure the LED keypads (1686H, 1686V
and 1689):
3.3.1 CONFIGURING THE 1686H, 1686V AN D 1689 KEYPADS V2.0 OR HIGHER
The keypad’s zone number, EOL definition and tamper switch are programmed through the control panels
programmi ng mode. To do so:
PLEASE NOTE: After two minutes, the keypad exits programmin g mode.
Key [1] - Keypad Zone Selection
Key [1] determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF
(not illuminated), the keypad’s zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypad’s zone
is Keypad Zone 2. Refer to Table 4 on page 16 for more information.
Key [1] OFF - Keypad Zone 1 (default)
Key [1] ON - Keypad Zone 2
Key [2] - EOL Definition
Key [2] determines the keypad zones EOL definition. When key [2] is OFF (not illuminated), EOL is
disabled and the keypad zone will use the on-board EOL resistor. When key [2] is ON (illuminated), EOL is
enabled and the keypad zone requires that an external EOL resistor be connected (refer to Spectra
1738EX and 1738 Control Panel Overview on page 4 and Spectra 1728EX and 1728 Control Panel
Overview on page 5 for more details).
Key [2] OFF - EOL disabled
Key [2] ON - EOL enabled (default)
Key [3] - On-Board Tamper
Key [3] enables or disables the keypads on-board tamper switch. When key [3] is OFF (not illuminated),
the tamper switch is disabled. When key [3] is ON (illuminated), the tamper switch is enabled.
Key [3] OFF - On-board tamper switch disabled
Key [3] ON - On-board tamper switch enabled
PLEASE NOTE: The keypad can be ordered with or without a tamper switch. If the keypad has
no tamper switch, key [3] will be OFF by default. If the keypad has a tamper switch, key [3]
will be ON by default.
3.3.2 CONFIGURING THE 1686H, 1686V AN D 1689 KEYPADS PRIOR TO V2.0
The keypad’s zone number and EOL definition are defined through the jumpers located on the PCB board.
The jumpers are as follows:
J1 - Keypad Zo ne Select J umper
Jumper J1 determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When the jumper
is OFF, the keypads zone is Keypad Zone 2. When the jumper is ON, the keypads zone is Keypad Zone 1.
Refer to Table 4 on page 16 for more information.
J1 OFF - Keypad Zone 2
J1 ON - Keypad Zone 1
How Do I Configure The Keypad?
STEP 1: Press [ENTER]
STEP 2: Enter your [INSTALLER CODE] (default: 000000 or 0000)
STEP 3: Pr ess the [PG] (1686H /V) / [FN C 1] (1689) key and hold i t for 3 seconds.
STEP 4: Press the desired key ([1] to [3]. See below)
STEP 5: Press [ENTER] to exit programming mode