24 REFERENCE & INSTALLATION MANUAL
6.3 REGULAR ARMING SWITCHES TO FORCE ARMING
Section [131 ]: Arming/Disar min g Options
Option [2] OFF = Regular Arming Switches to Force Arming Disabled (default)
Option [2] ON = Regul ar Arming Switches to For ce Arming Enabled
With this feature enabled, the control panel will always Force arm instead of Regular arm when a valid User Access
Code with the Force Arming Option is entered. In installations where the user must always Force arm when leaving
the protected area, this feature allows users to Force arm without pressing the [FORCE] key before enteri ng their
User Access Code. This feature is not to be used with UL installations.
6.4 RESTRICT ARMING ON BATTERY FAIL
Section [130 ]: Arming/Disar min g Options
Option [5] OFF = Permit arming on battery failure (default)
Option [5] ON = Restrict arming on battery failure
If this option is enabled, the control panel will not arm the system if the control panel detects that the backup battery
is disconnected, that its fuse is blown, or that the battery voltage drops to less than 10.5V. The control panel will not
arm the system until all battery trouble conditions are rectified.
6.5 RESTRICT ARMING ON TAMPER FAILURE
Section [130 ]: Arming/Disar min g Options
Option [6] OFF = Permit arming on tamper failure (default)
Option [6] ON = Restrict arming on tamper failure
If this option is enabled, the control panel will not arm the system if the control panel detects a tamper trouble on one
or more zones. The control panel will not arm the system until all tamper trouble conditions are rectified.
This feature will not function if the Tamper Recognition Options (see page 27) are disabled or whenever
the tampered zone is bypassed and the Tamper Bypass Options (see page 27) have been enab led.
6.6 TIMED AUTO-ARMING
Section [133] = Partition 1, [134] = Partition 2
Option [1] OFF = Ti med Auto-Arming Disabled (default)
Option [1] ON = Timed Auto-Arming Enabled
Each partition can be programmed to arm every day at the time specified by the Auto-Arm Ti mer. The Auto-Arming
Options (see section 6.8) determine the partition's arming method. Any open zones detected when a partition is
Auto-Armed will be bypassed regardless of their definition (except 24hr. zones). The control panel will enter a 60-
second Exit Delay period before arming the system. At this point, Auto-Arming can be cancelled by entering a valid
access code. Once the partition has successfully armed, the control panel can transmit the Timed Auto-Arming
repor t code programmed in section [172].
Example: To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-Arming for partition 2 by turning
on option [1] in section [134]. Then key in 18:15 into section [112].
6.6.1 AUT O-ARM TIMER
Section [111] = Partition 1, [112] = Partition 2
Select the section corresponding to the desired par tition and program the time (use the 24-hour clock i .e.
6:30PM = 18:30) that you wish the control panel to attempt to arm the selected partition and/or send the
Late to Close report code.
6.7 NO MOVEMENT AUTO-ARMING
Section [133] = Partition 1, [134] = Partition 2
Option [2] OFF = No Movement Auto-Arming Disabled (default)
Option [2] ON = No Movement Auto-Arming Enabled
If no movement occurs in a partition's protected area for the period specified by the No Movement Timer (see
below), the control panel can automatically arm that partition. The Auto-Arming Option described in section 6.8 of
this manual determines the partition's arming method. Any open zones detected when a partition is Auto-Armed will