20 REFERENCE & INSTALLATION MANUAL
5.6.2 STA NDA RD 24HR. FIR E ZONE
1728/EX:
Sections [001] to [005]: Zones 1 to 5, First Digit = 8
1738/EX:
Sections [001] to [007]: Zones 1 to 7, First Digit = 8
Whenever a Standard 24Hr. Fire Zone opens, whether it
is armed or disarmed, the control panel will generate the
following:
The contr ol panel can send the corresponding Alarm
Report Code from sections [187] to [190].
If a tamper/wiring fault occurs on a Fire Zone, the
control panel can send a Fire Loop Trouble report
code pr ogrammed in section [206] to the Central
Station. The keypads will display a Fire Loop Trouble
in their Tr oubl e Displa y (see page 46).
Alarms are always audible regardless of other
settings. Fir e alarms generate an intermittent (pulsed)
bell/siren output signal as shown in Figure 5.3.
For information on how to connect smoke detector s to
the control panel, refer to Fire Circuits on page 10.
5.6.3 DELAYED FIRE ZONE
1728/EX:
Sections [001] to [005]: Zones 1 to 5, First Digit = 9
1738/EX:
Sections [001] to [007]: Zones 1 to 7, First Digit = 9
When a Delayed 24Hr. Fire Zone opens, whether it is
armed or disarmed, the control panel wi ll react as show n
in Figure 5.2. Delayed 24Hr. Fire Zones are commonly
used in residential homes where a smoke detector often
generates fal se al arms (i.e. burning bread, etc.).
If the ATZ feature is enabled when using any
type of Fire Zone, the control panel will disable the “doubled zone (see Zo ne Doubling on
page 22).
Figure 5.3: Bell Output During Fire Alarm
5.7 ZONE PARTITION ASSIGNMENT
Sections [001] to [016]: Zones 1 to 16
The control panel provides the option of partitioning the security system into two completely independent systems.
As demonstrated in Figur e 5-1 on page 18, sections [001] to [016] represent zones 1 through 16 respectively, where
the second digit in each of these sections repr esents the zone's partition assignment. The zone is assigned to
Partition 1 if second digit = 1, Partition 2 if second digit = 2, or both partitions is second digit = 3. For details on
Partitioning, refer to page 39.
5.8 ZONE OPTIONS
As demonstrated in Figure 5.1, sections [001] to [016] represent zones 1 through 16 respectively. After entering the
first two digits, select one or more of the following Zone Options by using the Multiple Feature Select Programming
Method (see page 11):
Delayed Fire Zone
is triggered
Activate bell/siren output & delay
report transmission for 30 seconds.
Yes
Any key on
keypad pressed
within 30
seconds?
De-activate bell/siren output and
delay report transmission an
additional 90 seconds.
Problem
corrected?
Latch alarm and
transmit report code
END
Alarm Disabled
Yes
Yes
No
Problem
corrected within
30 seconds?
Yes
No
No
Fi
gure
5
.
2
:
D
e
l
aye
d
24H
r.
Fi
re
Z
one