50 REFERENCE & INSTALLATION MANUAL
One-Touch Regular Arming
Press and hold the [ENTER] key for 3 seconds* to arm all zones in the partition.
One-Touch Force Arming
Press and hold the [FORCE] key for 3 seconds* to bypass any open Force Zones.
One-Touch Bypass Programming
Press and hold the [BYP] key for 3 seconds* to access Bypass Programming Mode.
One-Touch Stay Arming
Press and hold the [STAY] key for 3 seconds* to arm all zones not defined as Stay Zones.
Fast Exit - When the system is already Stay Armed:
• To Exit and Stay Arm: Press and hold the
[STAY]
key for 3 seconds*. The system will switch to Exit Delay. At the end of
the Exit Delay period, the system will return to Stay Arming.
• To Exit and Regu lar Arm: Press and hold the
[
ENTER
]
key for 3 seconds*. The system will switch to Exit Delay. At the end
of the Exit Delay period, the control panel will switch to Regular Arming.
• To Exit and Force A rm: Press and hold the
[FORCE]
key for 3 seconds*. The system will switch to Exit Delay. At the end
of the Exit Delay period, the control panel will switch to Force Arming.
12.10 KEYSWITCH ARMING
A keyswitch can be used to arm and disarm the system. Assign the keyswitch to a specific partition and program the
keyswitch to Stay or Regular Arm the assigned partition. Also program the keyswitch to function as a Maintained or
Momentary keyswitch. To arm the system using a Maintained Keyswitch, set the keyswitch to the ON position. To
disarm the system set the keyswitch to the OFF position. To arm the system using a Momentary Keyswitch, set the
keyswitch to the ON position then turn it back to the OFF position. Repeating this sequence will disarm the system.
12.11 PANIC ALARMS
In case of emergency, the Spe ct ra system provides up to three panic alar ms. These panic al arms, if programmed, will
immediately generate an alarm after pressing and holding two specific keys for two seconds, as described below.
Press and hold keys [1] and [3] for a panic alarm.
Press and hold keys [4] and [6] for a panic or medical alarm.
Press and hold keys [7] and [9] for a panic or fire alarm.
12.12 AUTO-ARMING
Each partition can be programmed to arm every day at the time specified by the Auto-Arm Timer or for the period
specified by the No Movement Timer. The user can program the Auto-Arm Timer by using the System Master Code,
Master Code 1 or Master Code 2. Please note that the control pa nel wil l enter a 60 -second Exit Del ay pe ri od before
arming the system. At this point, Auto-Arming can be cancelled by entering a valid access code. UL Note: N ot to be
used with UL installations.
12.13 ALARM MEMORY DISPLAY
A record of all alarm situations that occur will be stored in memory. After disarming the system, pressing the [MEM]
key will display which zones were in alarm during the alarm period. To exit the Alarm Memory Display, press the
[CLEAR] key. The control panel will erase the contents of the alarm memory every time the system is armed.
12.14 PROGRAMMING CHIME ZONES
Users can program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a
rapid intermittent beep tone (B EEP -BE EP-BEE P-BEEP ) advising the user every time it is opened. Each keypad must be
Chime Programmed separately.
10-ZONE LED KEYPAD:
Press and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For
example, press and hold the [1] key to enable chiming on zone 1. If after pressing and holding a key, the keypad
* If you have access to both partitions after activating a one-touch feature, press the key corresponding to the
desir ed partition. To select both partitions, press the [1] key then after the confirmation beep press the [2] key.