SPECTRA SERIES 35
backup telephone number after every fai led attempt. If no backup telephone number is programmed, the control
panel will never report to the backup telephone number. Also, refer to Delay Between Dialing Attempts on page 35.
Example: The system is armed and zone 1 has been breached causing an alarm. If option [3] is off and option [4] is
on in section [137], the control panel will attempt to communicate with Central Station Telephone Number 2 in order
to transmit the Zone 1 Alarm Report Code programmed in section [187].
8.8 DIALING METHOD
Section [135 ]: Dialer Options
Option [4] OFF = Pulse D ial ing. ( Al so, refer to Pul se Ratio)
Option [4] ON = Tone/DTMF Dialing (default)
8.9 PULSE RATIO
Section [135 ]: Dialer Options
Option [5] OFF = European Pulse R atio of 1:2
Option [5] ON = U.S.A. Pulse Ratio of 1:1.5 (default)
When using Pulse dialing, you can select one of two Pulse Ratios. Although most European countries use the 1:2
pul se ratio, the 1:1.5 ratio may provi de better results in some cases. The same appli es for North American countries.
If the 1:1.5 pul se ratio is not pr ovi ding the desir ed r esults, the 1:2 ratio may be used.
8.10 BELL ON COMMUNICATION FAILURE
Section [135 ]: Dialer Options
Option [6] OFF = Bell On Communication Failure Disabled (default)
Option [6] ON = Bell On Communication Failure Enabled
If the control panel fails to communicate with the central station when the system is armed, it will enable the BE LL
output, setting off any bells or sirens connected to the output.
8.11 DIAL TONE DELAY
Section [136 ]: Dialer Options
Option [5] OFF = Dialer will continue to dial if no dial tone is present after 4 seconds (default).
Option [5] ON = Dialer will hang-up if no dial tone is present after 16 seconds
8.12 MAXIMUM DIALING ATTEMPTS
Section [0 81 ]
001 to 016 attempts, Default = 8 attempts
The value programmed in section [081] determines how many times the control panel will re-dial the same Central
Station Telephone Number before proceeding to the next number.
8.13 DELAY BETWEEN DIALING ATTEMPTS
Section [0 82 ]
000 to 255 seconds, Default = 20 seconds
This delay determines the amount of time the control panel will wait between each dialing attempt.
8.14 ALTERNATE DIAL OPTION
Section [136 ]: Dialer Options
Option [4] OFF = Alternate Dial Disabled (default)
Option [4] ON = Alternate D ial Enabled
With option [4] off, the control panel will dial the backup telephone number programmed in section [153] after all
attempts to one Central Station Telephone Number have failed (see section 8.12). With option [4] on, the control
panel will dial the backup telephone number after every failed attempt.