D
IGIPLEX
NE C
ONTROL
P
ANEL
21
6.2.4 PGM Activation (Utility Key)
When option [3] is enabled, the keyswitch can activate a PGM. When a
keyswitch is defined with the PGM Activation option, the Keyswitch Partition
Assignment and Keyswitch Options are disabled. To program a Keyswitch
to activate a PGM:
1) Program the Activation Event of a PGM output with the Utility Key
Event corresponding to the desired keyswitch (see PGM
Programming Table in the Programming Guide: Event Group 048).
2) Enable option [3] in the section corresponding to the desired
keyswitch.
If the Utility Key events from 1 to 8 are chosen as Activation Events, the
PGM will activate whether the keyswitch or the keys on the keypad are
used. Utility Key events from 9 to 32 are only generated when keyswitches
from 9 to 32 with this option enabled are used:
6.3 K
EYSWITCH
P
ARTITION
A
SSIGNMENT
The control panel provides the option of partitioning the security system into
eight completely independent systems. Therefore, each keyswitch must be
assigned to one partition as shown in Figure 6-1 on page 20. For details on
Partitioning, see section 12.7 on page 35.
6.4 K
EYSWITCH
O
PTIONS
Each keyswitch zone can be programmed with one or more of the options
below as shown in Figure 6-1 on page 20.
6.4.1 Stay/Instant Disarm Option (Keyswitch)
When option [4] is enabled, the keyswitch can only disarm assigned Stay or
Instant Armed partitions. The Arm Only Option (see section 6.4.2) must be
disabled for this feature to function. When option [4] is disabled, the
keyswitch can disarm partitions armed using any arming method.
6.4.2 Arm Only (Keyswitch)
When option [5] is enabled, the keyswitch can arm assigned partitions, but
cannot disarm any partitions. The type of arming is determined by the other
Keyswitch Options selected.
6.4.3 Regular Arming (Keyswitch)
When options [6] to [8] are disabled, the keyswitch arming option will
default to Regular Arming (see section 16.1).
6.4.4 Stay Arming (Keyswitch)
Activating the keyswitch will bypass any zones defined as Stay Zones (see
section 5.5.3) in the selected partition. All other zones will remain activated.
For more information on Stay Arming, refer to section 16.2.
6.4.5 Force Arming (Keyswitch)
Activating the keyswitch will arm the selected partition bypassing any open
zones defined as Force Zones (see section 5.5.4) at the time of arming. For
more information on Force Arming, refer to section 16.4.
6.4.6 Instant Arming (Keyswitch)
This option is identical to Stay Arming except that all armed zones will
become Instant Zones (see section 5.3.4). For more information on Instant
Arming, refer to section 16.3.
Only one of the arming options (Stay, Force, Instant and Regular)
can be selected.
Utility Key
Event
Keypad Keyswitch
1 Keys [1] & [2] 1
2 Keys [4] & [5] 2
3 Keys [7] & [8] 3
4Keys [
CLEAR
] & [0] 4
5 Keys [2] & [3] 5
6 Keys [5] & [6] 6
7 Keys [8] & [9] 7
8Keys [0] & [
ENTER
]8
9 to 32 --- 9 to 32