20 R
EFERENCE
& I
NSTALLATION
M
ANUAL
The DigiplexNE control panel can support up to 32 keyswitch zones in addition to the 96 standard zones. A keyswitch allows a user to arm or disarm a
system by pressing a key or by toggling a keyswitch. The keyswitches are connected to the hardwired input terminals of either the control panel, zone
expansion modules or the keypad. For installation instructions, see section 3.9 on page 9. Keyswitches must be programmed as described in this section
(see Figure 6-1).
Figure 6-1: Keyswitch Programming
6.1 K
EYSWITCH
N
UMBERING
Keyswitch Numbering allows you to assign any hardwired input in the
system to any of the 32 keyswitch zones in the control panel. It identifies
where the keyswitch is connected and which keyswitch zone is assigned to
the keyswitch (see Figure 6-2).
Figure 6-2: Example of Keyswitch Numbering
6.2 K
EYSWITCH
D
EFINITIONS
Keyswitch Definitions determine how the control panel reacts when a
keyswitch is activated.
6.2.1 Keyswitch Disabled
Disables keyswitch input.
6.2.2 Momentary Keyswitch
To arm a partition using the Momentary Keyswitch, turn on the keyswitch for
approximately three seconds then turn it off. Repeating this sequence will
disarm the system. The selected Keyswitch Option (see section 6.4)
determines the type of arming.
6.2.3 Maintained Keyswitch
To arm a partition using the Maintained Keyswitch, turn the switch from the
ON
to the
OFF
position. To disarm a partition set the keyswitch in the
ON
position. The selected Keyswitch Option (see section 6.4) determines the
type of arming. If the keyswitch’s Arm Only option is enabled, the control
panel will not perform any action when the switch is in the on position.
Press & hold the
[0]
key
Keyswitch Definition
First Digit
Keyswitch Partition
Assignment
Second Digit
Keyswitch Options
Feature Select
Enter the module's 8-digit
[
SERIAL
NUMBER
]
where the
keyswitch is installed.
Enter the 3-digit
[
INPUT
NUMBER
]
where the
keyswitch is connected.
Key-in
[
INSTALLER
CODE
]
Press
[
ENTER
]
Key-in 4-digit
[
SECTION
]
Select
one only
Keyswitch Parameters
Sections
[0601]
to
[0632]
represent
keyswitches 1 to 32 respectively
Select
one only
Keyswitch Numbering
Sections
[0501]
to
[0532]
represent
keyswitches 1 to 32 respectively
Set options
Keyswitch Definitions
[0] Disabled (default)
[1]
Momentary Keyswitch
[2] Maintained Keyswitch
[3] PGM Activation Only
(Becomes a Utility Key)
Keyswitch Partition Assignment
[0] Not assigned to partitions (default)
[1] Assigned to Partition 1
[2] Assigned to Partition 2
[3] Assigned to Partition 3
[4] Assigned to Partition 4
[5] Assigned to Partition 5
[6] Assigned to Partition 6
[7] Assigned to Partition 7
[8] Assigned to Partition 8
Keyswitch Options
Default = all off
[1] to [3] Future Use
[4] Stay/Instant Disarm
[5] Arm Only
[6] Stay Arming*
[7] Force Arming*
[8] Instant Arming*
*Select one only; if all are off, defaults to
regular arming.
Control Panel
SN#: 020000A2
Keyswitch B
Keyswitch C
Keyswitch
Zone # Section Serial# Input#
Keyswitch A: 1 = [0501] 020000A2 001
Keyswitch B: 2 = [0502] 34000041 002
Keyswitch C: 3 = [0503] 34000041 006
Input 2
Input 6
Keyswitch A
Input 1
Input Terminals
1 2 3 4 5 6 7 8
C
OMMUNICATION
N
ETWORK
Zone Expansion Module
SN#: 34000041
Input Terminals
1 2 3 4 5 6 7 8
Komentarze do niniejszej Instrukcji