(Default = disabled) The ATZ feature is a software oriented feature that
enables two detection devices to be installed per hardwired input terminal
(section 3.15 on page 13 and see section 3.14 on page 13). Each detection
device has its own zone, displays its zone status on the keypad and sends
its own alarm codes. Fire Zones cannot be doubled.
5.3 Z
ONE
D
EFINITIONS
The 16 zone definitions from Figure 5-1 on page 16 are described below.
When an alarm occurs, the control panel can send a report, activate the bell
output and display the alarm in the Alarm Memory.
5.3.1 Zone Disabled
Disables the corresponding zone. Zones are disabled by default.
5.3.2 Entry Delays 1 and 2
(Default Entry Delay 1= 030, Entry Delay 2 = 060) When an armed zone
defined as an Entry Delay opens, the control panel will not generate an
alarm until the Entry Delay Timer elapses. A zone defined as Entry Delay 1
follows the Entry Delay 1 Timer of its assigned partition. Likewise, a zone
defined as Entry Delay 2 follows the Entry Delay 2 Timer of its assigned
partition.
For example, if zone 1 is assigned to Partition 5 and is defined as Entry
Delay 1, the timer follows the amount programmed in [3511].
Each partition includes two Entry Delay Timers. To program an Entry Delay
Timer, key in the desired 3-digit delay value (001 to 255 seconds) into the
corresponding section.
Entry Delay zones are commonly used at the entry/exit points (i.e. front/
back door or garage). Using different Entry Delays is useful when one entry
point requires a longer delay than another.
These are the same timers used for Stay Delay zones (see section
5.3.14).
5.3.3 Follow Zones
If an armed Follow zone opens, the control panel generates an alarm. If an
armed Entry Delay zone (see section 5.3.2) opens before the Follow zone,
the control panel waits until the end of the Entry Delay before generating an
alarm. If more than one Entry Delay zone opens before the Follow zone,
the control panel waits until the end of the first Entry Delay before
generating an alarm. This feature is commonly used when a motion
detector is protecting the area occupied by the entry point keypad. This will
prevent the motion detector from causing an alarm when a user enters
through the entry point to disarm the system.
5.3.4 Instant Zones
When an armed Instant zone opens, the control panel immediately
generates an alarm. Instant zones are commonly used for windows, patio
doors, skylights and other perimeter type zones.
5.3.5 24Hr Buzzer Zones
Whenever a 24Hr Buzzer zone opens, whether the zone is armed or
disarmed, the control panel activates the keypad buzzer to indicate that the
zone was breached. The control panel will report the alarm, but will not
enable the bell/siren output. Enter any valid access code on the keypad to
stop the buzzer.
The keypads must be assigned to the same partition as the
24Hr Buzzer zone or the buzzer will not activate.
5.3.6 24Hr Burglary Zones
When a 24Hr Burglary zone opens, whether the system is armed or
disarmed, the control panel will immediately generate a burglary alarm.
5.3.7 24Hr Hold-up Zones
When a 24Hr Hold-up zone opens, whether it is armed or disarmed, the
control panel will immediately generate an alarm. The SIA FSK reporting
format includes specific codes to identify the alarm as a Hold-up Alarm.
5.3.8 24Hr Gas Zones
When a 24Hr Gas zone opens, whether it is armed or disarmed, the control
panel will immediately generate an alarm. The SIA FSK reporting format
includes specific codes to identify the alarm as a Gas Alarm.
5.3.9 24Hr Heat Zones
When a 24Hr Heat zone opens, whether it is armed or disarmed, the control
panel will immediately generate an alarm. The SIA FSK reporting format
includes specific codes to identify the alarm as a Heat Alarm.
5.3.10 24Hr Water Zones
When a 24Hr Water zone opens, whether it is armed or disarmed, the
control panel will immediately generate an alarm. The SIA FSK reporting
format includes specific codes to identify the alarm as a Water Alarm.
5.3.11 24Hr Freeze Zones
When a 24Hr Freeze zone opens, whether it is armed or disarmed, the
control panel will immediately generate an alarm. The SIA FSK reporting
format includes specific codes to identify the alarm as a Freeze Alarm.
5.3.12 Delayed 24Hr Fire Zone
The Delayed 24Hr Fire Zone definition from Figure 5-3: on page 18 is
commonly used in residential homes where a smoke detector often
generates false alarms (i.e. cigarette smoke, burning bread, etc.). A zone
programmed as Fire becomes normally open (will not function as normally
closed) and requires an EOL resistor.
Input Doubled Zone Input
Input 01 Input 13 (ATZ of Input 01)
Input 02 Input 14 (ATZ of Input 02)
Input 03 Input 15 (ATZ of Input 03)
Input 04 Input 16 (ATZ of Input 04)
Input 05 Input 17 (ATZ of Input 05)
Input 06 Input 18 (ATZ of Input 06)
Input 07 Input 19 (ATZ of Input 07)
Input 08 Input 20 (ATZ of Input 08)
Input 09 (DGP2-ZX4 Input 01) Input 21 (ATZ of Input 09)
Input 10 (DGP2-ZX4 Input 02) Input 22 (ATZ of Input 10)
Input 11 (DGP2-ZX4 Input 03) Input 23 (ATZ of Input 11)
Input 12 (DGP2-ZX4 Input 04) Input 24 (ATZ of Input 12)
Partition 1
Entry Delay 1 Timer: [3111]
Entry Delay 2 Timer: [3112]
Partition 5
Entry Delay 1 Timer: [3511]
Entry Delay 2 Timer: [3512]
Partition 2
Entry Delay 1 Timer: [3211]
Entry Delay 2 Timer: [3212]
Partition 6
Entry Delay 1 Timer: [3611]
Entry Delay 2 Timer: [3612]
Partition 3
Entry Delay 1 Timer: [3311]
Entry Delay 2 Timer: [3312]
Partition 7
Entry Delay 1 Timer: [3711]
Entry Delay 2 Timer: [3712]
Partition 4
Entry Delay 1 Timer: [3411]
Entry Delay 2 Timer: [3412]
Partition 8
Entry Delay 1 Timer: [3811]
Entry Delay 2 Timer: [3812]