Enable or disable the options as required for each User Access Code as
shown in Figure 13-1.
13.6 P
ARTITION
A
SSIGNMENT
Each of the 998 User Access Codes can be assigned to one or more
partitions. Users can only arm, disarm and view the status of the partitions
assigned to their User Access Codes. Select one or more of the partitions
for each User Access Code as shown in Figure 13-1 on page 38.
If no partition assignment is selected, the User Access Code will
only be able to activate PGMs.
13.7 A
CCESS
C
ONTROL
In addition to the User Access Code options, the following options can be
programmed when Access Control is enabled: Access Level, Schedule,
Access Options and Access Card. For details on Access Control, see
section 14 on page 40.
The System Master Code and User Access Codes with the Full
Master feature enabled can also program the Access Level,
Schedule, Access User Options, and Access Card using another
method for programming.
The System Master Code has access to all doors all the time.
Only the cards serial number and the choice of arming
method can be changed. If the other options are changed, the
System Master Code will revert to its original programming.
13.7.1 Access Level Assignment
User Access Codes can only open the doors included in their assigned
Access Level (see section 14.5 on page 40). In the first set of brackets,
enter the two-digit Access Level number (00 to 15, 00 = unrestricted) to be
assigned to that User Access Code.
13.7.2 Schedule Assignment
Schedules determine the hours, days and holidays that User Access Codes
can open the doors in their assigned Access Level (see section 14.6). In
the second set of brackets, enter the two-digit Primary Schedule number
(00 to 15, 00 = unrestricted) to be assigned to that User Access Code .
13.7.3 Access Control Options
The Access Control Options define how each Access Card can arm or
disarm the partitions. To arm the partition(s) assigned to the door, a valid
card is presented to the reader twice within approximately 5 seconds while
the door remains closed. For the card to be valid, it must be presented
during its assigned Schedule, within its assigned Access Level and be
assigned to the keypads assigned partitions depending on the Door
Access Mode (see section 14.10). Enable or disable the options as
required for each Access Card as shown in Figure 13-1.
13.7.4 Access Card Assignment
The Access Card is activated by assigning its serial number to the User
Access Code. Digiplex NE supports 26-bit Wiegand proximity cards and
readers (recommended: Position Technologys CR-R880-A reader and CR-
R700 Series cards). Enter the serial number manually or present the
Access Card to the keypads reader and its serial number will register
automatically.
Option Feature Description
[1] [2]
OFF OFF
Master disabled
User cannot create or modify other User
Access Codes.
ON OFF
Master enabled
User can create new User Access Codes
with default options only, can program
PINs and User Labels.
ON ON
Full Master enabled
User can create or modify User Access
Codes with the same partition assignment
and program the User Options, Partition
Assignment (can assign only partitions the
Master Code has access to), Access
Control features, PINs and User Labels.
[3] Duress
A Duress enabled User Access Code can
arm or disarm the partition and can
immediately transmit a silent alarm to the
Monitoring Station.
[4] Bypass
User can program bypass entries as
described in section 16.6.
[5] Arm Only
User can arm assigned partitions, but
cannot Disarm.
[6] Stay or Instant Arm
User can Stay Arm or Instant Arm (see
section 16.2) assigned partitions.
[7] Force Arm
User can Force Arm assigned partitions
(see section 16.4)
[8] User Menu Access
Option [8] ON = User can access all its
assigned partitions, regardless of the
keypads partition assignment.
Option [8] OFF = User can only access the
partitions assigned to both itself and the
keypad.
Option Feature Description
[1] Activate Card
ON = Card assigned to the User Access
Code is activated and can be used when
Access Control is enabled.
OFF = Card is disabled, but the User
Access Code remains unaffected. This can
be used to disable a lost or stolen card
without deleting the User Access Code.
[2] Card can Disarm
Card can unlock Door and disarm assigned
partitions. User Option [5]: Arm Only must
be disabled for this feature to function.
[3]
Card with Extended
Unlocked Period
Card uses the Door Unlocked Period
Extension feature (see Digiplex/DigiplexNE
LCD Keypad and Access Control LCD
Keypad Reference & Installation Manual).
[4] [5]
OFF OFF
Arming Disabled Cannot arm partitions
ON OFF
Regular Arm Card can Regular Arm.
OFF ON
Stay Arm Card can Stay Arm.
ON ON
Force Arm Card can Force Arm.
[6]
Add Tolerance
Windows to
Schedules
Card and Code use the Schedule
Tolerance Windows (see section 9.3.3 on
page 30 and section 14.9 on page 41).
[7]
Code follows
Schedule
ON = Code is only valid during assigned
Schedule (see section 13.7.2).
OFF = Code is valid at all times.
[8]
Card to Unlock and
Code to Disarm
ON = A door contact must be installed on
the Door, the Door must be assigned to a
zone (section 5.1) and the zone defined as
an Entry Delay. A valid Card can unlock the
Door, but cannot disarm the partition. If the
partition is armed, the Entry Delay is
triggered and a User Access Code must be
entered to disarm the area. User Option [5]:
Arm Only and Access Control Option [2]:
Card can Disarm must be disabled for this
feature to function.
OFF = A valid Card can unlock the Door
and disarm the partition.
Przeglądanie stron 40