28 REFERENCE & INSTALLATION MANUAL
8.8.1 Maximum Dialing Attempts**
SECTION [3056]
(Default = 008) The number (001 to 255, 000 = 8 attempts) programmed
into section [3056] determines how many times the control panel will dial
the same Monitoring Station Telephone Number before proceeding to the
next number. Also refer to section 8.8.3.
** UL Note: For UL Listed systems, the maximum dialing attempts must be
set to 5 to 10 attempts between the DGP-NE96’s two telephone lines.
8.8.2 Delay Between Dialing Attempts
SECTION [3054]
(Default = 020) This delay will determine the amount of time the control
panel will wait between dialing attempts. This delay can be set from 001 to
127 seconds.
8.8.3 Alternate Dialing Option
SECTION [3037]: OPTION [6]
(Default = disabled) With option [6] enabled in section [3037], the control
panel dials the selected backup telephone number after every failed
attempt to contact a Monitoring Station Telephone Number. Otherwise
(option [6] off), the control panel only dials the backup telephone number
after the Maximum Dialing Attempts (see section 8.8.1) to one Monitoring
Station Telephone Number fail.
8.9 PAGER DELAY
S
ECTION [3057]
(Default = 060) When using the Pager Reporting Format (see section
8.7.6), the control panel will wait for the delay period programmed into
section [3057] before uploading the report codes to the pager. This is to
allow time for the pager system to provide a dial tone or to bypass the
welcome message before sending the data. Enter any value between 001
and 127 to determine Pager Delay in seconds.
8.10 RECENT CLOSE DELAY
(Default = 000) If, after arming the partition, an alarm is generated within
the programmed period, the control panel will transmit the Recent Close
report code programmed into section [3933]. Enter any value between 001
and 255 to determine Recent Close Delay in seconds.
8.11 POWER FAILURE REPORT DELAY
S
ECTION [3058]
(Default = 030) The control panel will delay the transmission of the AC
Failure report code programmed into section [3941] by the period
programmed into section [3058]. Enter any value between 001 and 255 to
determine Power Failure Report Delay in minutes.
8.12 AUTO TEST REPORT
S
ECTION [3037]: OPTION [3] AND [4] AND
S
ECTIONS [3040], [3041], [3042] AND [3043]
The control panel can transmit the test report code programmed into
section [3902] every hour (Hourly Test Transmission) or after a period of
time (Auto Test Report Period).
8.13 DISARM REPORTING OPTIONS
(Default = disabled) When option [7] is disabled, the control panel sends
the Disarming Report Codes (see section 8.2) every time the partition is
disarmed. When option [7] is enabled, the control panel sends the
Disarming Report Codes to the Monitoring Station only when the partition is
disarmed following an alarm. Select the section that corresponds to the
desired partition and enable or disable option [7]:
8.14 ZONE RESTORE REPORT OPTIONS
S
ECTION [3037]: OPTION [8]
(Default = disabled) When option [8] is disabled, the control panel sends
the Zone Alarm Restore report codes to the Monitoring Station when the
Bell Cut-Off Timer elapses (see section 7.2) or when the alarm is disarmed.
When option [8] is enabled, the control panel sends the Zone Alarm
Restore report codes (see section 8.2) to the Monitoring Station as soon as
the zone returns to normal (zone closure) or upon disarming.
8.15 AUTO REPORT CODE PROGRAMMING
When using either the Contact ID or SIA Reporting Formats (see section
8.7), the control panel can automatically program a set of default report
codes. However, the Contact ID Reporting Format can be modified using
the manual programming method (see section 8.7.4 & section 8.7.5) to
program remaining report codes or to change some of the defaults. From
programming mode (see section 3.4) enter any of the following sections to
set the indicated report codes with the default values (FF) from the
Automatic Report Codes List in the Programming Guide:
[3] Telephone Number 3 [7] Backup on Number 3
[4] Telephone Number 4 [8] Backup on Number 4
Partition 1: [3109] Partition 3: [3309] Partition 5: [3509] Partition 7: [3709]
Partition 2: [3209] Partition 4: [3409] Partition 6: [3609] Partition 8: [3809]
Option Feature Description
[3] [4]
OFF OFF
Auto Test
Report
Period
(default)
After the number of days (000 to 255, default =
000) programmed into section [3040] elapse, the
control panel can transmit the report code at the
time (00:00 to 23:59, default = 00:00)
programmed into section [3041].
ON OFF
Hourly Test
Transmission
The control panel transmits the test report code at
the same time every hour. Program the minute of
each hour (00:00 to 00:59, default = 00:00) when
the test report should be sent into section [3041].
ON ON
Timed Test
Transmission
when Armed/
Disarmed
When armed: The control panel transmits the test
report code at regular intervals while the partition
is armed. Program the number of minutes (000 to
255, default 005) between each transmission in
section [3042].
When disarmed: The control panel transmits the
test report code at regular intervals while the
partition is disarmed. Program the number of
minutes (000 to 255, default = 060) between each
transmission in section [3043].
Partition 1: [3123] Partition 3: [3323] Partition 5: [3523] Partition 7: [3723]
Partition 2: [3223] Partition 4: [3423] Partition 6: [3623] Partition 8: [3823]
Section Description
[4030] Resets all the report code sections to 00 (cleared).
[4031] Sets all the report code sections to FF (defaults).
Section Sets to Defaults (FF) Reset Sections
[4032]
Zone Alarm and Restore Report Codes
Tamper and Restore Report Codes
[0201] to [0296]
[4033]
Keyswitch Arming Report Codes
Keyswitch Disarming Report Codes
Access Code Arming Report Codes
Access Code Disarming Report Codes
[0701] to [0732]
[0801] to [0832]
[2001] to [2099]
[2101] to [2199]
[4034] Special System Report Codes [3900] to [3909]