DIGIPLEXNE CONTROL PANEL 17
5.2.4 Generates a Utility Key Event on Open
SECTIONS [0601] TO [0632]: FIRST DIGIT = 3
When option [3] is enabled, a Utility Key Event will be generated whenever
the keyswitch input is opened (see Table 14 on page 51). This option can
be used to activate or deactivate one or more of DigiplexNE’s PGM outputs.
When a keyswitch is defined with the Generate a Utility Key Event on Open
option, the Keyswitch Partition Assignment and Keyswitch Options are
disabled. To program a Keyswitch to generate a Utility Key Event:
1) Program the Activation Event of a PGM output with the Utility Key
Event corresponding to the desired keyswitch (see PGM
Programming Table in the Programming Guide: Event Group 048).
2) Enable option [3] in the section corresponding to the desired
keyswitch.
5.2.5 Generates a Utility Key Event on Open and Close
SECTIONS [0601] TO [0632]: FIRST DIGIT = 4
When option [4] is enabled, a Utility Key Event will be generated whenever
the keyswitch input is opened and closed. As a result, the Utility Key Events
increase from 32 to 64 events when option [4] is enabled; one event for
each state (open and closed). See Table 14 on page 51.
This option can be used to activate or deactivate one or more of
DigiplexNE’s PGM outputs. When a keyswitch is defined with the Generate
a Utility Key Event on Open and Close option, the Keyswitch Partition
Assignment and Keyswitch Options are disabled. To program a Keyswitch
to generate a Utility Key Event:
1) Program the Activation Event of a PGM output with the Utility Key
Event corresponding to the desired keyswitch (see PGM
Programming Table in the Programming Guide: Event Group 048).
2) Enable option [4] in the section corresponding to the desired
keyswitch.
5.3 KEYSWITCH PARTITION ASSIGNMENT
S
ECTIONS [0601] TO [0632]: SECOND DIGIT = 1 TO 8
The control panel provides the option of partitioning the security system into
eight completely independent systems. Therefore, each keyswitch must be
assigned to one partition as shown in Figure 5-1 on page 16. For details on
Partitioning, see section 11.9 on page 32.
5.4 KEYSWITCH OPTIONS
Each keyswitch zone can be programmed with one or more of the options
below as shown in Figure 5-1 on page 16.
5.4.1 Stay/Instant Disarm Option (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [4]
When option [4] is enabled, the keyswitch can only disarm assigned Stay or
Instant Armed partitions. The Arm Only Option (see section 5.4.2) must be
disabled for this feature to function. When option [4] is disabled, the
keyswitch can disarm partitions armed using any arming method.
5.4.2 Arm Only (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [5]
When option [5] is enabled, the keyswitch can arm assigned partitions, but
cannot disarm any partitions. The type of arming is determined by the other
Keyswitch Options selected.
5.4.3 Regular Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [6] TO [8]
When options [6] to [8] are disabled, the keyswitch arming option will
default to Regular Arming (see section 15.1).
5.4.4 Stay Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [6]
Activating the keyswitch will bypass any zones defined as Stay Zones (see
section 4.5.3) in the selected partition. All other zones will remain activated.
For more information on Stay Arming, refer to section 15.2.
5.4.5 Force Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [7]
Activating the keyswitch will arm the selected partition bypassing any open
zones defined as Force Zones (see section 4.5.4) at the time of arming. For
more information on Force Arming, refer to section 15.4.
5.4.6 Instant Arming (Keyswitch)
SECTIONS [0601] TO [0632]: OPTION [8]
This option is identical to Stay Arming except that all armed zones will
become Instant Zones (see section 4.3.4). For more information on Instant
Arming, refer to section 15.3.