Digiplex DGP-NE96 - 7 - Programming Guide
Zone Programming
Zone Description Module Section 8-digit Serial Number Input# Section Define Assign Zone Options
1
________________________ _______________
[0001]
___/___/___/___/___/___/___/___ ___/___/___
[0101]
___ ___
1 2 3 4 5 6 7 8
2
________________________ _______________
[0002]
___/___/___/___/___/___/___/___ ___/___/___
[0102]
___ ___
1 2 3 4 5 6 7 8
3
________________________ _______________
[0003]
___/___/___/___/___/___/___/___ ___/___/___
[0103]
___ ___
1 2 3 4 5 6 7 8
4
________________________ _______________
[0004]
___/___/___/___/___/___/___/___ ___/___/___
[0104]
___ ___
1 2 3 4 5 6 7 8
5
________________________ _______________
[0005]
___/___/___/___/___/___/___/___ ___/___/___
[0105]
___ ___
1 2 3 4 5 6 7 8
6
________________________ _______________
[0006]
___/___/___/___/___/___/___/___ ___/___/___
[0106]
___ ___
1 2 3 4 5 6 7 8
7
________________________ _______________
[0007]
___/___/___/___/___/___/___/___ ___/___/___
[0107]
___ ___
1 2 3 4 5 6 7 8
8
________________________ _______________
[0008]
___/___/___/___/___/___/___/___ ___/___/___
[0108]
___ ___
1 2 3 4 5 6 7 8
9
________________________ _______________
[0009]
___/___/___/___/___/___/___/___ ___/___/___
[0109]
___ ___
1 2 3 4 5 6 7 8
10
________________________ _______________
[0010]
___/___/___/___/___/___/___/___ ___/___/___
[0110]
___ ___
1 2 3 4 5 6 7 8
11
________________________ _______________
[0011]
___/___/___/___/___/___/___/___ ___/___/___
[0111]
___ ___
1 2 3 4 5 6 7 8
12
________________________ _______________
[0012]
___/___/___/___/___/___/___/___ ___/___/___
[0112]
___ ___
1 2 3 4 5 6 7 8
13
________________________ _______________
[0013]
___/___/___/___/___/___/___/___ ___/___/___
[0113]
___ ___
1 2 3 4 5 6 7 8
14
________________________ _______________
[0014]
___/___/___/___/___/___/___/___ ___/___/___
[0114]
___ ___
1 2 3 4 5 6 7 8
15
________________________ _______________
[0015]
___/___/___/___/___/___/___/___ ___/___/___
[0115]
___ ___
1 2 3 4 5 6 7 8
16
________________________ _______________
[0016]
___/___/___/___/___/___/___/___ ___/___/___
[0116]
___ ___
1 2 3 4 5 6 7 8
17
________________________ _______________
[0017]
___/___/___/___/___/___/___/___ ___/___/___
[0117]
___ ___
1 2 3 4 5 6 7 8
18
________________________ _______________
[0018]
___/___/___/___/___/___/___/___ ___/___/___
[0118]
___ ___
1 2 3 4 5 6 7 8
19
________________________ _______________
[0019]
___/___/___/___/___/___/___/___ ___/___/___
[0119]
___ ___
1 2 3 4 5 6 7 8
20
________________________ _______________
[0020]
___/___/___/___/___/___/___/___ ___/___/___
[0120]
___ ___
1 2 3 4 5 6 7 8
21
________________________ _______________
[0021]
___/___/___/___/___/___/___/___ ___/___/___
[0121]
___ ___
1 2 3 4 5 6 7 8
22
________________________ _______________
[0022]
___/___/___/___/___/___/___/___ ___/___/___
[0122]
___ ___
1 2 3 4 5 6 7 8
23
________________________ _______________
[0023]
___/___/___/___/___/___/___/___ ___/___/___
[0123]
___ ___
1 2 3 4 5 6 7 8
Input 2
Hardwired
Device B
Control Panel
SN#:020000A2
APR3-ZX8 Module
SN#: 34000041
Input 5
Detector A
SN#: 21000033
C
OMMUNICATION
N
ETWORK
Input Terminals
1 2 3 4 5 6 7 8
Detector A:
Hardwired Device A:
Hardwired Device B:
Hardwired Device C:
Zone#
1 =
2 =
3 =
4 =
Section#
[0001]
[0002]
[0003]
[0004]
Serial#
21000033
1A000252
020000A2
34000041
Input#
N/A
N/A
002
005
Keypad
SN#: 1A000252
Keypad Zone
Hardwired
Device C
Hardwired
Device A
Input Terminals
1 2 3 4 5 6 7 8
Combus
When option [1] in section [3030] is enabled for PGM1
to act as a zone input for two-wire smoke detectors,
the control panel will recognize PGM1 as input number
255.
Zone Definitions
0 - Disabled (default) 8 - 24Hr Gas
1 - Entry Delay 1 9 - 24Hr Heat
2 - Entry Delay 2 A - 24Hr Water
3 - Follow B - 24Hr Freeze
4 - Instant C - Delayed 24Hr Fire
5 - 24Hr Buzzer D - Standard 24Hr Fire
6 - 24Hr Burglary E - Stay Delay 1
7 - 24Hr Hold-up F - Stay Delay 2
Zone Options
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled (default)
[3] Stay Zone
[4] Force Zone
[5] [6] Zone Alarm Type
off off Steady Alarm
off on Pulsed Alarm
on off Silent Alarm
on on Report Only
[7] Intellizone
[8] Delay before Transmission
Zone Partition Assignment
1 - Assigned to Partition 1 (default) 5 - Assigned to Partition 5
2 - Assigned to Partition 2 6 - Assigned to Partition 6
3 - Assigned to Partition 3 7 - Assigned to Partition 7
4 - Assigned to Partition 4 8 - Assigned to Partition 8
Zone Numbering
Sections [0001] to [0096] represent zones
1 through 96. This feature allows you to
assign an addressable or hardwired
detection device to the desired zone.
Enter 3-digit [
INPUT NUMBER] of the
Module to which the hardwired detection
device is connected. NOTE: No input
number is required for Addressable
Detectors, door contacts, or Keypad
Zones.
Enter 8-digit [
SERIAL NUMBER] of the
Addressable Detector, door contact, or
Module to which the hardwired detection
device is connected.
Zone Parameters
Sections [0101] to [0196] represent zones 1 through 96. This feature defines the
type of zone, its partition assignment and the zone’s options.